The Building Research Institute
Warsaw - Poland
Test facilities for walls
| Transmitting room dimensions: |
|
||||
|---|---|---|---|---|---|
| Receiving room dimensions: |
|
||||
| Trasmitting room volume: | 100 m3 | ||||
| Receiving room volume: | 93 m3 | ||||
| Test opening dimensions: |
|
||||
| Border of the niche to fix the specimens in: |
CONCRETE | ||||
| Noise generator: | |||||
| Loudspeakers positions: | FIXED | ||||
| Microphones type: | ROTATING | ||||
| Diffusing elements: | |||||
| Number of microphones positions: |
1 | ||||
| Number of source positions: | 2 |
Maximum achievable Sound Reduction
Index (Rmax):
| 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | Hz |
| 44.5 | 44.4 | 52.1 | 54.8 | 56.1 | 60.4 | 63.8 | 67.6 | 73.4 | 75.6 | 77.8 | 79.5 | 79 | 75.6 | 75.6 | 71.7 | dB |
Rwmax = 68 dB
Press Here for the cross-sections and the geometry of the laboratory.