DELTA Acoustics & Vibrations
Århus - Danemark
Test facilities for walls
| Transmitting room dimensions: |
|
|||
|---|---|---|---|---|
| Receiving room dimensions: |
|
|||
| Trasmitting room volume: | 118 m3 | |||
| Receiving room volume: | 62 m3 | |||
| Test opening dimensions: |
|
|||
| Border of the niche
to fix the specimens in: |
CONCRETE | |||
| Noise generator: | BROAD BAND | |||
| Loudspeakers positions: | MOVING | |||
| Microphones type: | ROTATING | |||
| Diffusing elements: | area 13.2 m2 | |||
| Number of microphones
positions: |
1 | |||
| Number of source positions: | 1 |
Maximum achievable Sound Reduction
Index (Rmax):
| 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | Hz |
| 51.1 | 54 | 58.7 | 62.4 | 68.2 | 73.5 | 77.9 | 82.1 | 85.2 | 87 | 88.9 | 90 | 92 | 93 | 93 | 94 | dB |
Rwmax = 78 dB